4001754-21
PORTRAIT
Installation & Owners Manual
This manual contains instructions to install the EN-
GINE ONLY. A front trim kit is REQUIRED to install
the engine as it affects the framing cavity and posi-
tion of the engine. A barrier screen is provided with
the front or trim kit. Refer to the manual supplied
with the front for framing and nishing.
— Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
— Installation and service must be
performed by a quali ed installer, service
agency or the gas supplier.
Ce guide est disponible en français sur demande.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
! WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
INSTALLER
Leave this manual
with the appliance.
CONSUMER
Retain this manual
for future reference.
Please read this manual
BEFORE installing and
operating this appliance.
DV Gas Fireplace Heater
530ILN/ILP (logs), 530ICN/ICP (coals),
530IRN/IRP (rocks)
©2015, Miles Industries Ltd. All rights reserved.
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - PORTRAIT

4001754-21PORTRAITInstallation & Owner’s ManualThis manual contains instructions to install the EN-GINE ONLY. A front trim kit is REQUIRED to inst

Page 2 - Table of Contents

10Remote Control OperationSETTING THE TIMESETTING ºC/24-HOUR OR ºF/12-HOUR CLOCKMODES OF OPERATIONNOTE: Manual mode can also be reached by pressing ei

Page 3 - Safety Precautions

11Remote Control OperationSETTING THE ON / OFF TEMPERATURES• Briefl y press SET button to scroll to TEMP (sun) mode. Hold the SET butt

Page 4 - Safety and Your Fireplace

12Remote Control OperationSETTING PROGRAM TIMERS• You can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle.• The Prog

Page 5 - 36” (0.9 m)

13OptionsAUTOMATIC TURN DOWNAUTOMATIC SHUT OFFLOW BATTERY INDICATIONHANDSET / RECEIVER MATCHRemote handset: The battery icon will show when t

Page 6 - Owner’s Information

14Lighting InstructionsWARNING: If you do not follow these instructions exactlyD¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJSURSHUW\GDPDJHSHUVRQDOLQMXU

Page 7 - in flame

15State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage RequirementsFor all side wall horizontally vented gas fueled equipment install

Page 8 - Valve Switch

16Commonwealth of Massachusetts(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved

Page 9

17Specifi cationsApprovals and CodesThis appliance is certifi ed to ANSI Z21.88–2014/CSA 2.33–2014 American National Standard/CSA Standard for Vented Ga

Page 10 - INFORMATION

18Dimensions, Clearance and FramingThe dimensions, clearances and framing vary with each applications and with the front trim installed. Refer to the

Page 11 - Remote Control Operation

19VentingAll horizontal pipe runs must be graded 1/4 inch per foot upwards in the direction of the exhaust fl ow. The fi nal pipe length, when terminati

Page 12

2Table of ContentsDesigned and Manufactured by / forMiles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1Tel. 604-984

Page 13

20HORIZONTALTERMINATION2-PIECEWALLTHIMBLEHORIZONTALTERMINATION2-PIECEWALLTHIMBLEPIPELENGTHPIPELENGTHPIPELENGTHPIPELENGTH817VAK817VAKPIPELENGTH90˚ ELBO

Page 14 - TO TURN OFF GAS TO APPLIANCE

21Important Installer Notice – Weather Sealing & Vapor BarriersIt is the installer’s responsibility to ensure that vent installations through exte

Page 15 - Commonwealth of Massachusetts

22Horizontal Vent Termination Location• The vent terminal must be located on an outside wall or through the roof.• This direct vent appliance is des

Page 16

23Use 845TG vent guard with a vent terminallocated at less than 7’ (2.13 m) above gradeV1V2H1H21” min.all aroundvertical pipe3” min.above top ofhoriz

Page 17 - The front trim/stove

244038363432302826242220181614121086422 4 6 8 10 12 14 16Top or Rear outlet1135How to R

Page 18 - (including all

25Co-Axial VentingAttaching Air Restrictors—Appliances with Vertical Vent Rise OnlyNo restrictors are required for appliances which only have a horizo

Page 19 - Square opening

26‘H’HorizontaloverhangVerticalwallTerminationcapStormcollarRoofflashingPlumber’s tapefixed to wall strapWall strapCeilingfirestopCeilingsupportOffset

Page 20 - Co-Axial Venting

27Co-Linear VentingCo-linear Venting into Existing Solid-Fuel Burning Fireplaces and ChimneysSee venting accessories list on pages 41–42 for allowable

Page 21 - Co-Axial Venting

28Co-Linear VentingAlternate to 556CLA/559CLT/559FSK Conversion for vertical terminationCo-Axial to Co-Linear Adapter10”10”3” Inlet & ExhaustColla

Page 22

29Convert from Rear Outlet to Top Outlet (co-axial venting)If installing with rear vent outlet, go to next step.1. Remove the top plate and seal by u

Page 23

3Safety Precautions!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing i

Page 24

30Prepare Vent OutletCo-axial Installations1. Fit the adapter 817VAK over the appliance vent collars pushing on fi rmly. Align the adapter so that the

Page 25

31InstallationConnect Gas Supply• It’s preferable to rough-in the gas line at this point before proceeding with the fi rebox installation.• The appli

Page 26

32InstallationInstall Ceramic Walls (530IL and IC only)The 530IL and 530IC engines are provided with a set of reversible walls. One side shows the bri

Page 27 - 556CLA Co-Linear Adapter

33InstallationInstall Ceramic Logs (530IL)1. Place the base log on the supports in the fi rebox and against the support at the fi rebox back.2. Locate

Page 28

34InstallationInstall Ceramic Coals (530IC)1. Place the base coal on the supports in the fi rebox and against the fi rebox back.2. Place the left fron

Page 29 - Installation

35InstallationInstall Ceramic Walls and Rocks (530IR)The ceramic rock set is packed in three cartons. Unpack each piece carefully to avoid damages. Yo

Page 30 - Exhaust

36InstallationTo get the optimal fl ame effect, it is important to place the rocks in their appropriate position. Each rock is embossed underneath with

Page 31

37InstallationRefi t and Check Window1. Place the window centrally against the engine unit and resting on the support at bottom front of the engine.2.

Page 32

38InstallationOpenOpenCloseCloseNGFlashback shield (for LPG only)LPG Air Shutter SliderOpenCloseLPGNG Air Shutter Slider & CoverCheck OperationTur

Page 33

39Packing Contents:1 Wall Bracket A2 Screws B1 Screw C2 Wall Anchor D1 Spacer E (detach before assembly)1 Wall Bracket FSwitch PlateAlternative 1Alt

Page 34

4Safety and Your FireplacePlease Follow These Important Child Safety Precautions and Recommendations,• Parts of your Valor Fireplace become extremel

Page 35

40Wiring DiagramOptional Wall Switch Kit 1265WSKConnectorRedYellowGV60 Wiring DiagramQUALIFIED INSTALLER

Page 36

41Approved Venting ComponentsApproved Direct Vent Suppliers for Valor Models 5306, 534, 650 and MF28Venting Parts Description Venting Parts Code / ava

Page 37

42Approved Venting Components Venting Parts DescriptionVenting Parts Code / availability by ManufacturerDURA-VENTSELKIRKICC EXCEL DIRECTSECURE VENT RL

Page 38

43Warranty1. Extended Warranty CoverageFor a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will

Page 39 - Alternative 3

44Replacement PartsCode Description Part no.1 Side wall support (2) 330A8982 Rear wall support 320B3204 Velcro strip 40000225 Port cover 4000828AH6 In

Page 40 - RedYellow

4512456789101112131419202122a22b232425262728293031333234353638394041424443a, 43b4546474841a41bNGLPG16a16b15a15bReplacement Parts44a49OWNER’S INFORMATI

Page 41 - Approved Venting Components

465152535455565758596061626350Replacement Parts646566676973717472757677787980817068For 530IRN/P onlyFor 530ILN/P and ICN/POWNER’S INFORMATION

Page 42

Thank You ...For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed in

Page 43 - Warranty

Tape ShutThank you for choosing a Valor ProductPostageneededMiles Industries Ltd.190 - 2255 Dollarton HighwayNorth Vancouver, BC V7H 3B1 CanadaF

Page 44 - Replacement Parts

5OWNER’S INFORMATIONOperating Your Fireplace for the First TimeWhen operating your new fi replace for the fi rst time, some vapors may be released due t

Page 45

6Cleaning Your FireplaceImportant - Glass cleaning - Mineral depositsOne of the by-products of the combustion process in a gas appliance is a mineral

Page 46

7Owner’s InformationThermocouple probe must be in flameCorrect fl ame appearanceWith LogsWith CoalsWith Rocks7. If the Hot Glass Warning plate h

Page 47 - Thank You

8ONOFFWall Switch (optional)Manual On/Off SwitchThermostatic Remote ControlLocating Lighting, Operation and Rating Information PlateThe Lighting, Oper

Page 48 - 190 - 2255 Dollarton Highway

9Remote Control OperationWhen the pilot is off, it will take 2 minutes before it can be lit again.TO TURN ON APPLIANCE TO TURN OFF APPLIANCEFLAME HEIG

Comments to this Manuals